A comparison of analytically and experimentally determined isothermal pressure losses in a heat-exchanger installation / by Wesley H. Hillendahl.

This report contains analytically and experimentally determined values of the pressure losses in a heat-exchanger installation. The analytical values of pressure loss were determined by adding together losses calculated from published data on elbows, diffusers, and straight ducts. Good agreemetn was...

Full description

Saved in:
Bibliographic Details
Main Author: Hillendahl, Wesley H.
Corporate Authors: United States. National Advisory Committee for Aeronautics, Ames Research Center
Other title:NACA Wartime Reports. Series A.
Format: Government Document Book
Language:English
Published: Washington, D.C. : National Advisory Committee for Aeronautics, [1945]
Series:Wartime Reports (United States. National Advisory Committee for Aeronautics) ; no. A26.
Subjects:

Norlin Library - Basement - Government Information - US

Holdings details from Norlin Library - Basement - Government Information - US
Call Number: Y 3.N 21/5:11/A26
Y 3.N 21/5:11/A26 Available Place a Hold