Water tests for determining post voiding behavior in the LMFBR [electronic resource]

The most serious of the postulated accidents considered in the design of the Liquid Metal Cooled Fast Breeder Reactor (LMFBR) is the Loss of Pipe Integrity (LOPI) accident. Analysis models used to calculate the consequences of this accident assume that once boiling is initiated film dryout occurs in...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access (via OSTI)
Corporate Author: Massachusetts Institute of Technology (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Cambridge, Mass. : Oak Ridge, Tenn. : Massachusetts Institute of Technology ; distributed by the Office of Scientific and Technical Information, U.S. Department of Energy, 1976.
Subjects:

Internet

Online Access (via OSTI)

Online

Holdings details from Online
Call Number: E 1.99: mit-el-76-005
E 1.99: mit-el-76-005 Available