Failure of a high-power pin in a simulated $3/s TOP accident [electronic resource] : Test E6 final report.

This report describes the Fuel Dynamics Test E6 and analyzes the test data. A cluster of six fresh FTR-type fuel pins surrounding a previously irradiated pin was tested to failure in a simulated $3/s FFTF accident. It is shown that: (1) the central 34.3-cm-long test pin is thermodynamically equivale...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access (via OSTI)
Corporate Author: Argonne National Laboratory (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C. : Oak Ridge, Tenn. : United States. Department of Energy. ; distributed by the Office of Scientific and Technical Information, U.S. Department of Energy, 1978.
Subjects:

Internet

Online Access (via OSTI)

Online

Holdings details from Online
Call Number: E 1.99:anl-78-73
E 1.99:anl-78-73 Available