Failure of a high-power pin in a simulated $3/s TOP accident [electronic resource] : Test E6 final report.
This report describes the Fuel Dynamics Test E6 and analyzes the test data. A cluster of six fresh FTR-type fuel pins surrounding a previously irradiated pin was tested to failure in a simulated $3/s FFTF accident. It is shown that: (1) the central 34.3-cm-long test pin is thermodynamically equivale...