Effect of several surface treatments on the strength of a glass ceramic-to-metal seal [electronic resource]

Test shells of Inconel 625, Inconel 718, 21-6-9 stainless steel, and Hastelloy, C-276 were plasma and/or chemically cleaned before sealing with a multi-component glass-ceramic-to-metal seal was evaluated using a hydrostatic burst test. The results show that plasma cleaning can be used to increase th...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access
Corporate Author: Mound Facility (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Miamisburg, Ohio : Oak Ridge, Tenn. : Mound Facility ; distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1982.
Subjects:

Internet

Online Access

Online

Holdings details from Online
Call Number: E 1.99:mlm-2893
E 1.99:mlm-2893 Available