Results of initial testing of the four stage RHEPP accelerator [electronic resource]
The low power checkout of the Repetitive High Energy Pulsed Power (RHEPP) pulse forming line (PFL) and linear induction voltage adder (LIVA) is complete. The accelerator has four LIVA cavities driven via coaxial cables from the PFL that utilizes magnetic switching to provide a 250-kV, 60-ns output p...