Final report on production test IP-289-I, Supplement 1, H reactor export flow test [electronic resource]

The raw water export system forms the last ditch water supply system to the ̀̀Ò̀ and ̀̀C̀̀ type reactors; in the event of electrical and steam power failure, the export system is designed to supply enough raw water coolant. After the original export orifice was modified twice, the export system was...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access
Corporate Authors: Hanford Atomic Products Operation (Researcher), Hanford Site (Wash.) (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C. : Oak Ridge, Tenn. : United States. Dept. of Energy ; distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1961.
Subjects:

Internet

Online Access

Online

Holdings details from Online
Call Number: E 1.99:hw--68462