HAZARDS SUMMARY REPORT FOR A TWO WATT STRONTIUM-90 FUELED THERMOELECTRIC GENERATOR [electronic resource]
A hazards survey was made of the Auxiliary Power Unit (APU) which utilizes the decay products from 8,300 c of Sr/sup 90/ and its daughter, Y/sup 90/ , to generate thermal energy. A diagram and description of the Sr/sup 90/-fueled APU are given. The location, temperature effects, emergency provisions...