Forced-air cooling of a WIPP mine drift. [Waste Isolation Pilot Plant] [electronic resource]

A one-dimensional model has been developed to predict the time, t*, required to cool a Waste Isolation Pilot Plant (WIPP) mine drift. Comparisons have been made with a two-dimensional model and are found to be in good agreement for four months less than or equal to t* less than or equal to two years...