Failure Surface Analysis of Polyimide/Titanium Notched Coating Adhesion Specimens [electronic resource]

Adhesively bonded joints of LaRC{trademark} PETI-5, a phenylethynyl-terminated polyimide, with chromic acid anodized titanium were fabricated and debonded interfacially. The adhesive-substrate failure surfaces were investigated using several surface analysis techniques. From Auger spectroscopy, fiel...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access
Corporate Author: Sandia National Laboratories (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C : Oak Ridge, Tenn. : United States. Dept. of Energy ; distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 2000.
Subjects:

Internet

Online Access

Online

Holdings details from Online
Call Number: E 1.99:sand2000-3137j
E 1.99:sand2000-3137j Available