Active Waste Materials Corrosion and Decontamination Tests [electronic resource]

Stainless steel alloys, 304L and 316L, were corrosion tested in representative radioactive samples of three actual Hanford tank waste solutions (Tanks AW-101, C-104, AN-107). Both the 304L and 316L exhibited good corrosion performance when immersed in boiling waste solutions. The maximum general cor...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access
Corporate Author: Pacific Northwest National Laboratory (U.S.) (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C : Oak Ridge, Tenn. : United States. Dept. of Energy ; distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 2000.
Subjects:

Internet

Online Access

Online

Holdings details from Online
Call Number: E 1.99: bnfl-rpt-039
E 1.99: bnfl-rpt-039 Available