Advanced combustion system for industrial boilers. Phase 2, Quarterly technical progress report, April--June 1990 [electronic resource]
(1) A ZrO₂ oxygen sensor was calibrated successfully over the concentration range from 0 to 21 percent O₂ at temperatures from ambient to 400°F. This inexpensive automotive sensor provides 8 signal which will be used to monitor and automatically control combustion conditions to maintain consistently...