Hydrostatic pressure testing of graphite/epoxy cylinder C6-1 [electronic resource]

This report details the design, fabrication, and testing of IM6 graphite cylinder C6-1, which achieved a record pressure in hydrotest without failure. Included are the details of the cylinder construction, the design calculations for stress and buckling, and the cylinder failure predictions. Also pr...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access
Corporate Author: Oak Ridge National Laboratory (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C. : Oak Ridge, Tenn. : United States. Dept. of Energy ; distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1992.
Subjects:

Internet

Online Access

Online

Holdings details from Online
Call Number: E 1.99:ornl/atd--64
E 1.99:ornl/atd--64 Available