A process control sensor for the glass industry [electronic resource]
The detailed analysis and testing of the modified sensing system is summarized by the following conclusions: Analyzer long term drift and short term noise improvements have resulted in inherent accuracies of about {plus minus} 1/2°C, about equivalent to the black body calibration source. Four differ...
Saved in:
Online Access: |
Online Access |
---|---|
Corporate Authors: | , |
Format: | Government Document Electronic eBook |
Language: | English |
Published: |
Washington, D.C. : Oak Ridge, Tenn. :
United States. Dept. of Defense ; distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy,
1992.
|
Subjects: |
Internet
Online AccessOnline
Call Number: |
E 1.99:doe/id/12781-2
|
---|---|