Influence of dissolved hydrogen on nickel alloy SCC in high temperature water [electronic resource]
Stress corrosion crack growth rate (SCCGR) tests of nickel alloys were conducted at 338 C and 360 C as a function of the hydrogen concentration in high purity water. Test results identified up to a 7 x effect of hydrogen levels in the water on crack growth rate, where the lowest growth rates were as...
Saved in:
Online Access: |
Online Access |
---|---|
Corporate Author: | |
Format: | Government Document Electronic eBook |
Language: | English |
Published: |
Washington, DC : Oak Ridge, Tenn. :
United States. Office of the Assistant Secretary for Nuclear Energy ; distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy,
1999.
|
Subjects: |
Internet
Online AccessOnline
Call Number: |
E 1.99:K--98155;CONF-990301--
|
---|---|
E 1.99:K--98155;CONF-990301-- | Available |