Effects of a high mean stress on the high cycle fatigue life of PWA 1480 and correlation of data by linear elastic fracture mechanics [microform] / by S. Majumdar and R. Kwasny.
"High-cycle fatigue tests using 5-mm-diameter smooth specimens were performed on the single crystal alloy PWA 1480 (001 axis) at 70° F (room temperature) in air and at 1000° F (538° C) in vacuum (10⁻⁶ torr). Tests were conducted at zero mean stress as well as at high tensile mean stress. The...