Diagnosis of Corrosion Process in Nuclear Power Plant Secondary Piping Structures [electronic resource]

Corrosion inside secondary pipe structures in Nuclear Power Plants is difficult to detect without intrusion. Statistical and machine learning techniques are used to predict corrosion using pipe vibration data. 3D accelerometers were used to record pipe vibration data in three directions using six se...