LMFBR leak detection systems for primary piping [electronic resource] : a preliminary evaluation.
A survey of sodium to gas leaks made several years ago showed the inadequacy of the then-used leak detection systems to detect large sodium leaks. In the cases analyzed, leak detection monitors detected only 19% of the leaks, instrumentation other than leak detectors accounted for 4%, and visual obs...
Saved in:
Online Access: |
Online Access (via OSTI) |
---|---|
Corporate Author: | |
Format: | Government Document Electronic eBook |
Language: | English |
Published: |
Washington, D.C : Oak Ridge, Tenn. :
United States. Energy Research and Development Administration ; distributed by the Office of Scientific and Technical Information, U.S. Department of Energy,
1976.
|
Subjects: |
MARC
LEADER | 00000nam a22000003u 4500 | ||
---|---|---|---|
001 | b9122558 | ||
003 | CoU | ||
005 | 20170329232833.3 | ||
006 | m o d f | ||
007 | cr ||||||||||| | ||
008 | 170512e19761001||| ot f0|||||eng|d | ||
035 | |a (TOE)ost709416 | ||
035 | |a (TOE)709416 | ||
040 | |a TOE |c TOE | ||
049 | |a GDWR | ||
072 | 7 | |a 21 |2 edbsc | |
086 | 0 | |a E 1.99:bnl-nureg--22000 | |
086 | 0 | |a E 1.99:bnl-nureg--22000 | |
088 | |a bnl-nureg--22000 | ||
245 | 0 | 0 | |a LMFBR leak detection systems for primary piping |h [electronic resource] : |b a preliminary evaluation. |
260 | |a Washington, D.C : |b United States. Energy Research and Development Administration ; |a Oak Ridge, Tenn. : |b distributed by the Office of Scientific and Technical Information, U.S. Department of Energy, |c 1976. | ||
300 | |a 16 p. : |b digital, PDF file. | ||
336 | |a text |b txt |2 rdacontent. | ||
337 | |a computer |b c |2 rdamedia. | ||
338 | |a online resource |b cr |2 rdacarrier. | ||
500 | |a Published through SciTech Connect. | ||
500 | |a 10/01/1976. | ||
500 | |a "bnl-nureg--22000" | ||
500 | |a Klamut, C. J.; Isaacs, H. S.; Weeks, J. R. | ||
520 | 3 | |a A survey of sodium to gas leaks made several years ago showed the inadequacy of the then-used leak detection systems to detect large sodium leaks. In the cases analyzed, leak detection monitors detected only 19% of the leaks, instrumentation other than leak detectors accounted for 4%, and visual observation accounted for 46%. Recent developments, primarily of aerosol type leak detections, have improved this situation substantially, but long-term performance data are not yet available for low leak rates. This preliminary evaluation reviews the types of leak detection systems proposed for CRBR and the available information on their performance and on the external corrosion of piping by sodium leaking into the N₂--O₂ blanketed atmosphere proposed for CRBR. | |
536 | |b EY-76-C-02-0016. | ||
650 | 7 | |a Leak Detectors. |2 local. | |
650 | 7 | |a Performance. |2 local. | |
650 | 7 | |a Sodium. |2 local. | |
650 | 7 | |a Clinch River Breeder Reactor. |2 local. | |
650 | 7 | |a Primary Coolant Circuits. |2 local. | |
650 | 7 | |a Leaks. |2 local. | |
650 | 7 | |a Corrosion. |2 local. | |
650 | 7 | |a Pipes. |2 local. | |
650 | 7 | |a Reviews. |2 local. | |
650 | 7 | |a Specific Nuclear Reactors And Associated Plants. |2 edbsc. | |
710 | 2 | |a Brookhaven National Laboratory. |4 res. | |
710 | 1 | |a United States. |b Energy Research and Development Administration. |4 spn. | |
710 | 1 | |a United States. |b Department of Energy. |b Office of Scientific and Technical Information. |4 dst. | |
856 | 4 | 0 | |u http://www.osti.gov/scitech/biblio/709416 |z Online Access (via OSTI) |
907 | |a .b91225589 |b 03-09-23 |c 05-12-17 | ||
998 | |a web |b 05-12-17 |c f |d m |e p |f eng |g |h 0 |i 1 | ||
956 | |a Information bridge | ||
999 | f | f | |i ae9f6254-5398-5fdc-975a-7f8d1f36aeaf |s 02854e0d-67b3-5007-9cb1-3c3d7bc0f92f |
952 | f | f | |p Can circulate |a University of Colorado Boulder |b Online |c Online |d Online |e E 1.99:bnl-nureg--22000 |h Superintendent of Documents classification |i web |n 1 |