Shearing-stress measurements by use of a heated element / H.W. Liepmann and G.T. Skinner.
The present report discusses the use of an insturment to determine the local skin-friction coefficient by measurement of heat transfer from small elements embedded in the surface. The range of application of such instruments is discussed and experimental data are presented to show that a simple inst...
Saved in:
Main Author: | |
---|---|
Corporate Author: | |
Other Authors: | |
Format: | Government Document Book |
Language: | English |
Published: |
Washington, D.C. :
National Advisory Committee for Aeronautics,
1954.
|
Series: | Technical note (United States. National Advisory Committee for Aeronautics) ;
3268. |
Subjects: |
MARC
LEADER | 00000cam a2200000Ia 4500 | ||
---|---|---|---|
001 | b9055162 | ||
003 | CoU | ||
008 | 101026e195411 dcua bt f000 0 eng d | ||
005 | 20231212012112.6 | ||
035 | |a (OCoLC)ocn671812201 | ||
035 | |a (OCoLC)671812201 | ||
040 | |a LHL |b eng |c LHL |d LHL |d OCLCF |d OCLCO |d OCLCQ |d COD | ||
049 | |a COD9 | ||
086 | 0 | |a Y 3.N 21/5:6/3268 | |
100 | 1 | |a Liepmann, H. W. |q (Hans Wolfgang), |d 1914-2009. |0 http://id.loc.gov/authorities/names/n83826999 |1 http://isni.org/isni/0000000081709695. | |
245 | 1 | 0 | |a Shearing-stress measurements by use of a heated element / |c H.W. Liepmann and G.T. Skinner. |
260 | |a Washington, D.C. : |b National Advisory Committee for Aeronautics, |c 1954. | ||
300 | |a 27 pages : |b illustrations ; |c 27 cm. | ||
336 | |a text |b txt |2 rdacontent. | ||
337 | |a unmediated |b n |2 rdamedia. | ||
338 | |a volume |b nc |2 rdacarrier. | ||
490 | 1 | |a National Advisory Committee for Aeronautics technical note ; |v 3268. | |
500 | |a "November 1954." | ||
500 | |a NACA TN Number 3268. | ||
504 | |a Includes bibliographical references. | ||
520 | 3 | |a The present report discusses the use of an insturment to determine the local skin-friction coefficient by measurement of heat transfer from small elements embedded in the surface. The range of application of such instruments is discussed and experimental data are presented to show that a simple instrument consisting of an ordinary hot-wire cemented into a groove in the surface can be used to obtain laminar and turbulent skin-friction coefficients with a single calibration. | |
583 | 1 | |a committed to retain |c 20230101 |d 20480101 |5 CoU |f Alliance Shared Trust |u https://www.coalliance.org/shared-print-archiving-policies. | |
650 | 0 | |a Heat |x Transmission |x Measurement. |0 http://id.loc.gov/authorities/subjects/sh2008121504. | |
650 | 0 | |a Skin friction (Aerodynamics) |0 http://id.loc.gov/authorities/subjects/sh85123197. | |
650 | 0 | |a Strains and stresses |x Measurement. | |
650 | 7 | |a Heat |x Transmission |x Measurement. |2 fast |0 (OCoLC)fst00953838. | |
650 | 7 | |a Skin friction (Aerodynamics) |2 fast |0 (OCoLC)fst01120142. | |
650 | 7 | |a Strains and stresses |x Measurement. |2 fast |0 (OCoLC)fst01134296. | |
700 | 1 | |a Skinner, George Tolmie. | |
710 | 1 | |a United States. |b National Advisory Committee for Aeronautics. |0 http://id.loc.gov/authorities/names/n79060141 |1 http://isni.org/isni/0000000106642010. | |
830 | 0 | |a Technical note (United States. National Advisory Committee for Aeronautics) ; |v 3268. |0 http://id.loc.gov/authorities/names/no2009017392. | |
907 | |a .b9055162x |b 08-13-20 |c 02-17-17 | ||
998 | |a pas |b 02-17-17 |c r |d m |e - |f eng |g dcu |h 0 |i 1 | ||
907 | |a .b9055162x |b 11-09-19 |c 02-17-17 | ||
944 | |a MARS - RDA ENRICHED | ||
907 | |a .b9055162x |b 06-20-17 |c 02-17-17 | ||
907 | |a .b9055162x |b 02-17-17 |c 02-17-17 | ||
948 | |a gro16/17:cjg | ||
999 | f | f | |i 1a3af48f-0699-56f4-a525-bb28f6d8a615 |s 45abff1e-e80c-5bd7-ac15-1b512273852f |
952 | f | f | |p Can circulate |a University of Colorado Boulder |b Boulder Campus |c Offsite |d PASCAL Offsite |e Y 3.N 21/5:6/3268 |h Superintendent of Documents classification |i document |m P204062608062 |n 1 |