Study to investigate the basic switching impulse insulation level requirements for a 1200 kV CGIT cable system [electronic resource]

A study was performed to determine the switching surge voltages a prototype 1200 kV CGIT cable may be exposed to under service conditions. The results of this study were used to establish the system's basic switching impulse insulation level requirements. An investigation was made of a suitable...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access
Corporate Author: Alabama A & M University (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C : Oak Ridge, Tenn. : United States. Department of Energy ; distributed by the Office of Scientific and Technical Information, U.S. Department of Energy, 1979.
Subjects:

MARC

LEADER 00000nam a22000003u 4500
001 b7710487
003 CoU
005 20140303000000.0
006 m o d f
007 cr |||||||||||
008 140422e19790701dcu ot f0|||||eng|d
035 |a (TOE)ost5857543 
035 |a (TOE)5857543 
040 |a TOE  |c TOE 
049 |a GDWR 
072 7 |a 24  |2 edbsc 
086 0 |a E 1.99:doe/et-2061-2 
086 0 |a E 1.99:doe/et-2061-2 
088 |a doe/et-2061-2 
245 0 0 |a Study to investigate the basic switching impulse insulation level requirements for a 1200 kV CGIT cable system  |h [electronic resource] 
260 |a Washington, D.C :  |b United States. Department of Energy ;  |a Oak Ridge, Tenn. :  |b distributed by the Office of Scientific and Technical Information, U.S. Department of Energy,  |c 1979. 
300 |a Pages: 190 :  |b digital, PDF file. 
336 |a text  |b txt  |2 rdacontent. 
337 |a computer  |b c  |2 rdamedia. 
338 |a online resource  |b cr  |2 rdacarrier. 
500 |a Published through SciTech Connect. 
500 |a 07/01/1979. 
500 |a "doe/et-2061-2" 
500 |a Pfleiderer, R. 
520 3 |a A study was performed to determine the switching surge voltages a prototype 1200 kV CGIT cable may be exposed to under service conditions. The results of this study were used to establish the system's basic switching impulse insulation level requirements. An investigation was made of a suitable CGIT model to be employed for use on the Westinghouse transient network analyzer. The model chosen was applicable for the cable when its sheaths are solidly grounded. This model was employed for each of the four cable lengths investigated. Cable lengths of 600 ft, 2 miles, 10 miles and 50 miles were investigated in four general system configurations, in all 47 systems were studied. 
536 |b EX-76-C-01-2061. 
650 7 |a Power Transmission.  |2 local. 
650 7 |a Electrical Equipment.  |2 local. 
650 7 |a Power Transmission Lines.  |2 local. 
650 7 |a Uhv Ac Systems.  |2 local. 
650 7 |a Underground Power Transmission.  |2 local. 
650 7 |a Electrical Insulation.  |2 local. 
650 7 |a Equipment.  |2 local. 
650 7 |a Switches.  |2 local. 
650 7 |a Ac Systems.  |2 local. 
650 7 |a Power Systems.  |2 local. 
650 7 |a Power Transmission And Distribution.  |2 edbsc. 
710 2 |a Alabama A & M University.  |4 res. 
710 1 |a United States.  |b Department of Energy.  |4 spn. 
710 1 |a United States.  |b Department of Energy.  |b Office of Scientific and Technical Information.  |4 dst. 
856 4 0 |u http://www.osti.gov/servlets/purl/5857543/  |z Online Access 
907 |a .b77104870  |b 03-07-23  |c 04-22-14 
998 |a web  |b 04-22-14  |c f  |d m   |e p  |f eng  |g dcu  |h 0  |i 1 
956 |a Information bridge 
999 f f |i 0289081f-25c1-5238-9858-0f1001ab9601  |s 070ab6f1-0dfe-524d-8cc3-31be5bd5d73b 
952 f f |p Can circulate  |a University of Colorado Boulder  |b Online  |c Online  |d Online  |e E 1.99:doe/et-2061-2  |h Superintendent of Documents classification  |i web  |n 1