Detection of electrically failed photovoltaic modules at MIT LL test sites [electronic resource]

The US Department of Energy has set a 20-year lifetime goal for terrestrial photovoltaic modules. In its capacity as a Photovoltaic Field Test and Application Center, Massachusetts Institute of Technology Lincoln Laboratory has established various experimental test sites throughout the United States...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access
Corporate Author: Massachusetts Institute of Technology (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C. : Oak Ridge, Tenn. : United States. Department of Energy. ; distributed by the Office of Scientific and Technical Information, U.S. Department of Energy, 1981.
Subjects:

MARC

LEADER 00000nam a22000003u 4500
001 b7709467
003 CoU
005 20140509224122.9
006 m o d f
007 cr |||||||||||
008 140801e19810201||| ot f0|||||eng|d
035 |a (TOE)ost6619943 
035 |a (TOE)6619943 
040 |a TOE  |c TOE 
049 |a GDWR 
072 7 |a 14  |2 edbsc 
086 0 |a E 1.99:doe/et/20279-112 
086 0 |a E 1.99:doe/et/20279-112 
088 |a doe/et/20279-112 
245 0 0 |a Detection of electrically failed photovoltaic modules at MIT LL test sites  |h [electronic resource] 
260 |a Washington, D.C. :  |b United States. Department of Energy. ;  |a Oak Ridge, Tenn. :  |b distributed by the Office of Scientific and Technical Information, U.S. Department of Energy,  |c 1981. 
300 |a Pages: 26 :  |b digital, PDF file. 
336 |a text  |b txt  |2 rdacontent. 
337 |a computer  |b c  |2 rdamedia. 
338 |a online resource  |b cr  |2 rdacarrier. 
500 |a Published through SciTech Connect. 
500 |a 02/01/1981. 
500 |a "doe/et/20279-112" 
500 |a Forman, S. E. 
520 3 |a The US Department of Energy has set a 20-year lifetime goal for terrestrial photovoltaic modules. In its capacity as a Photovoltaic Field Test and Application Center, Massachusetts Institute of Technology Lincoln Laboratory has established various experimental test sites throughout the United States, ranging in size from 1.5 to 100 kW of peak power. These sites contain modules from several manufacturers and serve as test beds for photovoltaic system components. Between May 1977 and the present, over 11,000 modules have been placed into service at these sites, with a total of approximately 250 electrical failures. In previous reports, emphasis has been placed on failure modes and the types of physical and electrical degradation found in modules. The methods used to detect these failures in operational photovoltaic power-generating systems are reported for several MIT Lincoln Laboratory test sites. 
536 |b AC02-76ET20279. 
650 7 |a Photovoltaic Power Supplies.  |2 local. 
650 7 |a Failures.  |2 local. 
650 7 |a Field Tests.  |2 local. 
650 7 |a Detection.  |2 local. 
650 7 |a Solar Cell Arrays.  |2 local. 
650 7 |a Electronic Equipment.  |2 local. 
650 7 |a Equipment.  |2 local. 
650 7 |a Solar Equipment.  |2 local. 
650 7 |a Power Supplies.  |2 local. 
650 7 |a Testing.  |2 local. 
650 7 |a Solar Energy.  |2 edbsc. 
710 2 |a Massachusetts Institute of Technology.  |4 res. 
710 1 |a United States.  |b Department of Energy.  |4 spn. 
710 1 |a United States.  |b Department of Energy.  |b Office of Scientific and Technical Information.  |4 dst. 
856 4 0 |u http://www.osti.gov/servlets/purl/6619943/  |z Online Access 
907 |a .b77094670  |b 03-07-23  |c 04-22-14 
998 |a web  |b 04-22-14  |c f  |d b   |e p  |f eng  |g    |h 0  |i 2 
956 |a Information bridge 
999 f f |i 0668c0f5-fc32-5e71-b772-093262e9ee1b  |s fdabc330-cb84-55f9-9b28-3190effcb5de 
952 f f |p Can circulate  |a University of Colorado Boulder  |b Online  |c Online  |d Online  |e E 1.99:doe/et/20279-112  |h Superintendent of Documents classification  |i web  |n 1