Effect of several surface treatments on the strength of a glass ceramic-to-metal seal [electronic resource]
Test shells of Inconel 625, Inconel 718, 21-6-9 stainless steel, and Hastelloy, C-276 were plasma and/or chemically cleaned before sealing with a multi-component glass-ceramic-to-metal seal was evaluated using a hydrostatic burst test. The results show that plasma cleaning can be used to increase th...