CE IGCC Repowering Project char filters. Topical report, November 1990--May 1993 [electronic resource]

The char filters are required to operate at 1000 degrees at a nominal internal pressure range of 256 to 294 psia. In the design used for estimating the demonstration plant, product gas and entrained char leave the gasifier heat exchanger at 1000°F and enter a char cyclone that separates a nominal 65...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access
Corporate Authors: ABB Combustion Engineering (Researcher), National Energy Technology Laboratory (U.S.) (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C. : Oak Ridge, Tenn. : United States. Dept. of Energy ; distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1993.
Subjects:

MARC

LEADER 00000nam a22000003u 4500
001 b7313696
003 CoU
005 20111025000000.0
006 m o d f
007 cr |||||||||||
008 130211e19930501dcu ot f0|||||eng|d
035 |a (TOE)ost10130999 
035 |a (TOE)10130999 
040 |a TOE  |c TOE 
049 |a GDWR 
072 7 |a 01  |2 edbsc 
086 0 |a E 1.99:doe/mc/26308--3639 
086 0 |a E 1.99:doe/mc/26308--3639 
088 |a doe/mc/26308--3639 
245 0 0 |a CE IGCC Repowering Project char filters. Topical report, November 1990--May 1993  |h [electronic resource] 
260 |a Washington, D.C. :  |b United States. Dept. of Energy ;  |a Oak Ridge, Tenn. :  |b distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy,  |c 1993. 
300 |a 32 p. :  |b digital, PDF file. 
336 |a text  |b txt  |2 rdacontent. 
337 |a computer  |b c  |2 rdamedia. 
338 |a online resource  |b cr  |2 rdacarrier. 
500 |a Published through the Information Bridge: DOE Scientific and Technical Information. 
500 |a 05/01/1993. 
500 |a "doe/mc/26308--3639" 
500 |a "DE94004060" 
500 |a "AZ0401010" 
500 |a Krawczyk, P.D. 
513 |a Interim;  |b 01/01/1990 - 12/31/1993. 
520 3 |a The char filters are required to operate at 1000 degrees at a nominal internal pressure range of 256 to 294 psia. In the design used for estimating the demonstration plant, product gas and entrained char leave the gasifier heat exchanger at 1000°F and enter a char cyclone that separates a nominal 65% of the char from the product gas. The product gas and remaining char discharge the cyclone to two parallel char filters each sized to handle 50% of the gas and char load. The char filters resemble conventional cylindrical bag filter modules use for gas filtration. The 12-ft. diameter vessels are constructed of carbon steel with insulating refractory linings. The refractory in the cones is lined with stainless steel to promote flow. The filters are designed to use any of three different high temperature filter media. Each type of filter is available in common diameters, and the tube sheet is arranged for a single filter diameter. The tube sheet is designed to accommodate movement and stress due to thermal expansion and differential pressure excursions. 
536 |b FC21-91MC26308. 
650 7 |a Design.  |2 local. 
650 7 |a Hot Gas Cleanup.  |2 local. 
650 7 |a Chars.  |2 local. 
650 7 |a Ce Entrained Fuel Process.  |2 local. 
650 7 |a Removal.  |2 local. 
650 7 |a Materials.  |2 local. 
650 7 |a Materials Testing.  |2 local. 
650 7 |a Coal Gasification.  |2 local. 
650 7 |a Performance Testing.  |2 local. 
650 7 |a Filters.  |2 local. 
650 7 |a Coal Gas.  |2 local. 
650 7 |a Filtration.  |2 local. 
650 7 |a Coal, Lignite, And Peat.  |2 edbsc. 
710 2 |a ABB Combustion Engineering.  |4 res. 
710 1 |a United States.  |b Department of Energy.  |4 spn. 
710 2 |a National Energy Technology Laboratory (U.S.).  |4 res. 
710 1 |a United States.  |b Department of Energy.  |b Office of Scientific and Technical Information.  |4 dst. 
856 4 0 |u http://www.osti.gov/servlets/purl/10130999/  |z Online Access 
907 |a .b73136967  |b 03-07-23  |c 02-11-13 
998 |a web  |b 02-11-13  |c f  |d m   |e p  |f eng  |g dcu  |h 0  |i 1 