An assessment of existing studies of wind loading on solar collectors / L.M. Murphy.
This paper discusses current design and testing procedures for wind loading. The test results corresponding to numerous wind tests on heliostats, parabolic troughs, parabolic dishes, and field mounted photovoltaic arrays are discussed and the applicability of the findings across the various technol...
Saved in:
Main Author: | |
---|---|
Corporate Authors: | , |
Format: | Government Document Book |
Language: | English |
Published: |
Golden, Colo. :
Solar Energy Research Institute,
1981.
|
Subjects: |
MARC
LEADER | 00000cam a2200000Ia 4500 | ||
---|---|---|---|
001 | b7135527 | ||
003 | CoU | ||
008 | 820701s1981 coua b f000 0 eng d | ||
005 | 20231211205557.5 | ||
035 | |a (OCoLC)ocm08566782 | ||
035 | |a (OCoLC)8566782 | ||
040 | |a KKC |c KKC |d IUL |d OCLCQ |d OCLCG |d WEA |d SOE | ||
049 | |a COD9 | ||
086 | 0 | |a E 1.28:SERI/TR-632-812 | |
100 | 1 | |a Murphy, L. M. |q (Lawrence Martin), |d 1941- |0 http://id.loc.gov/authorities/names/n80111362 |1 http://isni.org/isni/0000000084334016. | |
245 | 1 | 3 | |a An assessment of existing studies of wind loading on solar collectors / |c L.M. Murphy. |
260 | |a Golden, Colo. : |b Solar Energy Research Institute, |c 1981. | ||
300 | |a xiii, 35 pages : |b illustrations ; |c 28 cm. | ||
336 | |a text |b txt |2 rdacontent. | ||
337 | |a unmediated |b n |2 rdamedia. | ||
338 | |a volume |b nc |2 rdacarrier. | ||
500 | |a "SERI-TR-632-812." | ||
500 | |a February 1981. | ||
500 | |a Prepared for the U.S. Department of Energy under Contract Number EG-77-C-01-4042. | ||
504 | |a Includes bibliographical references (pages 29-31) | ||
520 | 3 | |a This paper discusses current design and testing procedures for wind loading. The test results corresponding to numerous wind tests on heliostats, parabolic troughs, parabolic dishes, and field mounted photovoltaic arrays are discussed and the applicability of the findings across the various technologies is assessed. One of the most significant consistencies in the data from all of the technologies is the apparent benefit provided by fences and field shielding. Taken in toto, these data show that load reductions of three or possibly more seem feasible, though a more thorough understanding of the phenomena involved must be attained before this benefit can be realized. It is recommended that the required understanding be developed to take advantage of this benefit and that field tests be conducted to correlate with both analyses and tests. | |
583 | 1 | |a committed to retain |c 20230101 |d 20480101 |5 CoU |f Alliance Shared Trust |u https://www.coalliance.org/shared-print-archiving-policies. | |
650 | 0 | |a Solar energy |x Research. |0 http://id.loc.gov/authorities/subjects/sh85124506. | |
650 | 0 | |a Solar collectors. |0 http://id.loc.gov/authorities/subjects/sh85124495. | |
710 | 2 | |a Solar Energy Research Institute. |0 http://id.loc.gov/authorities/names/n79061964 |1 http://isni.org/isni/0000000110161463. | |
710 | 1 | |a United States. |b Department of Energy. |0 http://id.loc.gov/authorities/names/n78034868 |1 http://isni.org/isni/0000000412615133. | |
907 | |a .b71355273 |b 09-08-21 |c 08-03-12 | ||
998 | |a pas |b 08-12-21 |c a |d m |e - |f eng |g cou |h 3 |i 1 | ||