Baseline and optional bench-scale testing of a chemical candle filter safeguard device [electronic resource]

This project was undertaken by the Energy and Environmental Research Center (EERC) to design, construct, and test the feasibility of a hot-gas filter safeguard device (SGD) to prevent the release of dust in the event of candle filter failure under both pressurized fluidized-bed combustion (PFBC) (ox...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access
Corporate Authors: Federal Energy Technology Center (U.S.) (Researcher), National Energy Technology Laboratory (U.S.) (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C : Oak Ridge, Tenn. : United States. Dept. of Energy ; distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 2000.
Subjects:

MARC

LEADER 00000nam a22000003u 4500
001 b6985899
003 CoU
005 20080205000000.0
006 m d f
007 cr |||||||||||
008 110824e20001101dcu ot f0|||||eng|d
035 |a (TOE)ost774907 
035 |a (TOE)774907 
040 |a TOE  |c TOE 
049 |a GDWR 
072 7 |a 01  |2 edbsc 
086 0 |a E 1.99:de--ac26-99ft40677-03 
086 0 |a E 1.99:de--ac26-99ft40677-03 
088 |a de--ac26-99ft40677-03 
245 0 0 |a Baseline and optional bench-scale testing of a chemical candle filter safeguard device  |h [electronic resource] 
260 |a Washington, D.C :  |b United States. Dept. of Energy ;  |a Oak Ridge, Tenn. :  |b distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy,  |c 2000. 
300 |a 14 pages :  |b digital, PDF file. 
336 |a text  |b txt  |2 rdacontent. 
337 |a computer  |b c  |2 rdamedia. 
338 |a online resource  |b cr  |2 rdacarrier. 
500 |a Published through the Information Bridge: DOE Scientific and Technical Information. 
500 |a 11/01/2000. 
500 |a "de--ac26-99ft40677-03" 
500 |a Hurley, J.P.; Swanson, M.L. 
513 |a Topical;  |b 09/29/2000. 
520 3 |a This project was undertaken by the Energy and Environmental Research Center (EERC) to design, construct, and test the feasibility of a hot-gas filter safeguard device (SGD) to prevent the release of dust in the event of candle filter failure under both pressurized fluidized-bed combustion (PFBC) (oxidizing) and integrated gasification combined cycle (IGCC) (reducing) operating conditions. The SGD must use existing filter system seals, gaskets, fixtures, and assemblies as much as possible. It must also activate quickly when a candle filter has failed, preferably preventing dust concentrations downstream of the SGD from exceeding 1 ppmw. In addition, the SGD must be able to operate in an inactive mode with minimal pressure drop, and its operation cannot be affected by repeated backpulse cleaning events of up to 3 psia and 1/2 second in duration. 
536 |b AC26-99FT40677. 
650 7 |a Fluidized-bed Combustion.  |2 local. 
650 7 |a Design.  |2 local. 
650 7 |a Testing.  |2 local. 
650 7 |a Gaskets.  |2 local. 
650 7 |a Gasification.  |2 local. 
650 7 |a Combined Cycles.  |2 local. 
650 7 |a Cleaning.  |2 local. 
650 7 |a Pressure Drop.  |2 local. 
650 7 |a Safeguards.  |2 local. 
650 7 |a Dusts.  |2 local. 
650 7 |a Coal, Lignite, And Peat.  |2 edbsc. 
710 2 |a Federal Energy Technology Center (U.S.).  |4 res. 
710 1 |a United States.  |b Department of Energy.  |4 spn. 
710 2 |a National Energy Technology Laboratory (U.S.).  |4 res. 
710 1 |a United States.  |b Department of Energy.  |b Office of Scientific and Technical Information.  |4 dst. 
856 4 0 |u http://www.osti.gov/servlets/purl/774907-fo809W/webviewable/  |z Online Access 
907 |a .b69858998  |b 03-06-23  |c 03-31-12 
998 |a web  |b 03-31-12  |c f  |d m   |e p  |f eng  |g dcu  |h 0  |i 1 
956 |a Information bridge 
999 f f |i 22728e43-c382-5ef4-83b5-fe45b03a6592  |s 41eeb7a3-7710-5412-b6b0-56cbec85e3a2 
952 f f |p Can circulate  |a University of Colorado Boulder  |b Online  |c Online  |d Online  |e E 1.99:de--ac26-99ft40677-03  |h Superintendent of Documents classification  |i web  |n 1