Heating Facilities [electronic resource] : Klamath County Road Department Shops, Klamath Falls, Oregon.

Maywood Industries is presently utilizing 118°F water pumped from a geothermal well about 1500 feet deep. The Klamath County Road complex presently heats about 13,000 square feet of space using electric and natural gas heaters. It is planned to increase the total heated area to nearly 24,000 square...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access
Corporate Author: Oregon Institute of Technology (Klamath Falls, Or. ). (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Portland, Ore. : Oak Ridge, Tenn. : United States. Bonneville Power Administration ; distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1980.
Subjects:

MARC

LEADER 00000nam a22000003u 4500
001 b6013916
003 CoU
006 m d f
007 cr un
008 100527e19801230oru st f0|||||eng|d
005 20230817214028.8
035 |a (TOE)ost6809416 
035 |a (TOE)6809416 
040 |a TOE  |c TOE 
049 |a GDWR 
072 7 |a 15  |2 edbsc 
086 0 |a E 1.99:doe/bp-15325-t2 
245 0 0 |a Heating Facilities  |h [electronic resource] :  |b Klamath County Road Department Shops, Klamath Falls, Oregon. 
260 |a Portland, Ore. :  |b United States. Bonneville Power Administration ;  |a Oak Ridge, Tenn. :  |b distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy,  |c 1980. 
300 |a Pages: 13 :  |b digital, PDF file. 
336 |a text  |b txt  |2 rdacontent. 
337 |a computer  |b c  |2 rdamedia. 
338 |a online resource  |b cr  |2 rdacarrier. 
500 |a Published through the Information Bridge: DOE Scientific and Technical Information. 
500 |a 12/30/1980. 
500 |a "doe/bp-15325-t2" 
520 3 |a Maywood Industries is presently utilizing 118°F water pumped from a geothermal well about 1500 feet deep. The Klamath County Road complex presently heats about 13,000 square feet of space using electric and natural gas heaters. It is planned to increase the total heated area to nearly 24,000 square feet. This study is based on eliminating the existing electrical and natural gas heaters and heating the entire 24,000 square feet geothermally. It was found to be practical and economically feasible to heat the road department shop complex geothermally. Capital cost is estimated to be $170,000. Annual energy savings for the enlarged facility would be 56,720 KWH of electricity and 36,924 therms of natural gas, with a first year value of $18,175. This savings, less operating costs, when applied with escalation considerations over a period of twenty years, result in a present worth of $382,385 when discounted at 8%. Thus, with 8% bonds financing of this project is economically attractive. (MHR) 
520 0 |a Geothermal Resources; Energy Conservation. 
536 |b AC79-79BP15325. 
650 7 |a Design.  |2 local. 
650 7 |a Diagrams.  |2 local. 
650 7 |a Space Heating.  |2 local. 
650 7 |a Wells.  |2 local. 
650 7 |a Heating Systems.  |2 local. 
650 7 |a Geothermal Heating.  |2 local. 
650 7 |a Geothermal Space Heating.  |2 local. 
650 7 |a Usa.  |2 local. 
650 7 |a Flowsheets.  |2 local. 
650 7 |a North America.  |2 local. 
650 7 |a Buildings.  |2 local. 
650 7 |a Geothermal Heating Systems.  |2 local. 
650 7 |a Economic Analysis.  |2 local. 
650 7 |a Geothermal Wells.  |2 local. 
650 7 |a Pacific Northwest Region.  |2 local. 
650 7 |a Feasibility Studies.  |2 local. 
650 7 |a Cost.  |2 local. 
650 7 |a Energy Balance.  |2 local. 
650 7 |a Oregon.  |2 local. 
650 7 |a Heating.  |2 local. 
650 7 |a Capital.  |2 local. 
650 7 |a Economics.  |2 local. 
650 7 |a Geothermal Energy.  |2 edbsc. 
710 2 |a Oregon Institute of Technology (Klamath Falls, Or.  |b ).  |4 res. 
710 1 |a United States.  |b Bonneville Power Administration.  |4 spn. 
710 1 |a United States.  |b Department of Energy.  |b Office of Scientific and Technical Information.  |4 dst. 
856 4 0 |u http://www.osti.gov/servlets/purl/6809416-Hx3COa/  |z Online Access 
907 |a .b6013916x  |b 03-06-23  |c 05-30-10 
998 |a web  |b 05-30-10  |c f  |d m   |e p  |f eng  |g oru  |h 0  |i 1 
956 |a Information bridge 
999 f f |i 4f1a11ae-5faf-5df6-837b-99f153c07bb4  |s e3aaf729-cc05-56d8-9692-b09992b54a8e 
952 f f |p Can circulate  |a University of Colorado Boulder  |b Online  |c Online  |d Online  |e E 1.99:doe/bp-15325-t2  |h Superintendent of Documents classification  |i web  |n 1