DWPF recycle stream corrosion tests [electronic resource]

Coupon immersion tests were performed on ASTM A537 Class 1 carbon steel in simulated DWPF recycle solutions at 90 ± 2°C, as part of the continuing effort to investigate the formation of shock-sensitive deposits. Coupons were partially immersed for four months in solutions of the same composition use...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access
Corporate Authors: Westinghouse Savannah River Company (Researcher), United States. Department of Energy. Savannah River Site (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C. : Oak Ridge, Tenn. : United States. Dept. of Energy ; distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1993.
Subjects:

MARC

LEADER 00000nam a22000003u 4500
001 b5949367
003 CoU
005 20080618000000.0
006 m d f
007 cr un
008 100524e19930421dcu st f0|||||eng|d
035 |a (TOE)ost10165056 
035 |a (TOE)10165056 
040 |a TOE  |c TOE 
049 |a GDWR 
072 7 |a 12  |2 edbsc 
086 0 |a E 1.99:wsrc-tr--93-233 
086 0 |a E 1.99:wsrc-tr--93-233 
245 0 0 |a DWPF recycle stream corrosion tests  |h [electronic resource] 
260 |a Washington, D.C. :  |b United States. Dept. of Energy ;  |a Oak Ridge, Tenn. :  |b distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy,  |c 1993. 
300 |a 8 p. :  |b digital, PDF file. 
336 |a text  |b txt  |2 rdacontent. 
337 |a computer  |b c  |2 rdamedia. 
338 |a online resource  |b cr  |2 rdacarrier. 
500 |a Published through the Information Bridge: DOE Scientific and Technical Information. 
500 |a 04/21/1993. 
500 |a "wsrc-tr--93-233" 
500 |a "DE93016151" 
500 |a Zapp, P.E. 
513 |a Topical;  |b 04/01/1993. 
520 3 |a Coupon immersion tests were performed on ASTM A537 Class 1 carbon steel in simulated DWPF recycle solutions at 90 ± 2°C, as part of the continuing effort to investigate the formation of shock-sensitive deposits. Coupons were partially immersed for four months in solutions of the same composition used previously at SRTC and at the DuPont Engineering Test Center (a salt solution containing 0.5 M hydroxide and 0.043 M nitrite). Shock-sensitive deposits were not seen on the coupons from this test. There was considerable general corrosion above the water line due to condensate and distilled water contact of the steel. New immersion tests are being planned for completion by September, 1993. The new test solution will reflect the recycle stream chemistry changes brought about by planned ammonia scrubbing in the DWPF. 
536 |b AC09-89SR18035. 
650 7 |a Radioactive Waste Facilities.  |2 local. 
650 7 |a Waste Storage.  |2 local. 
650 7 |a Corrosion Resistance.  |2 local. 
650 7 |a Temperature Range 0273-0400 K.  |2 local. 
650 7 |a Tanks.  |2 local. 
650 7 |a Solutions.  |2 local. 
650 7 |a Waste Processing.  |2 local. 
650 7 |a Savannah River Plant.  |2 local. 
650 7 |a Radioactive Wastes.  |2 local. 
650 7 |a Carbon Steels.  |2 local. 
650 7 |a Corrosion Protection.  |2 local. 
650 7 |a Corrosion Resistant Alloys.  |2 local. 
650 7 |a Management Of Radioactive And Non-radioactive Wastes From Nuclear Facilities.  |2 edbsc. 
710 2 |a Westinghouse Savannah River Company.  |4 res. 
710 1 |a United States.  |b Department of Energy.  |4 spn. 
710 1 |a United States.  |b Department of Energy.  |b Savannah River Site.  |4 res. 
710 1 |a United States.  |b Department of Energy.  |b Office of Scientific and Technical Information.  |4 dst. 
856 4 0 |u http://www.osti.gov/servlets/purl/10165056-WpPfSn/  |z Online Access 
907 |a .b59493677  |b 03-06-23  |c 05-25-10 
998 |a web  |b 05-25-10  |c f  |d m   |e p  |f eng  |g dcu  |h 0  |i 1 
956 |a Information bridge 
999 f f |i e29202e3-f475-5221-bf31-e3d947c9cf3f  |s 94e074ca-584a-5c00-8556-8af9318a925d 
952 f f |p Can circulate  |a University of Colorado Boulder  |b Online  |c Online  |d Online  |e E 1.99:wsrc-tr--93-233  |h Superintendent of Documents classification  |i web  |n 1