Long term laboratory corrosion monitoring of calcine bin set materials exposed to zirconia calcine [electronic resource]

Corrosion testing of Type 1025 carbon steel, 405, 304, 304L, 316L, and 347 stainless steels, and 6061-T6 aluminum were conducted in synthetic zirconia calcine to model long term corrosion performance of bin set material. Testing was conducted over a period of 17 years. The existing calcine bin set {...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access
Corporate Author: United States. Department of Energy. Idaho Operations Office (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C. : Oak Ridge, Tenn. : United States. Dept. of Energy ; distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1994.
Subjects:
Description
Summary:Corrosion testing of Type 1025 carbon steel, 405, 304, 304L, 316L, and 347 stainless steels, and 6061-T6 aluminum were conducted in synthetic zirconia calcine to model long term corrosion performance of bin set material. Testing was conducted over a period of 17 years. The existing calcine bin set {number_sign}1 is constructed of Type 405 stainless steel, 2 through 4 are constructed of Type 304 stainless steel and 5 through 7 are constructed of Type 304L stainless steel. The highest rate observed for Type 304L stainless steel was 8.1 × 10⁻⁷ inches per month. This would equal a wall thickness loss of about 5 mils after 500 years of storage. Currently, the established schedule for removal of corrosion test coupons from the calcine storage bins is at the end of the 10th, 100th, 250th, and 450th year of solid storage service. Very low corrosion rates and metal oxide data determined from the long term laboratory test, in conjunction with corrosion rates from the coupon assessment of the second bin set, indicate this schedule should be revised from 10 years to 50 years for the first assessment.
Item Description:Published through the Information Bridge: DOE Scientific and Technical Information.
06/01/1994.
"winco--1219"
"DE94015783"
Dirk, W.J.
Westinghouse Idaho Nuclear Co., Inc., Idaho Falls, ID (United States)