Grout gas generation test plan [electronic resource]

Disclosed are detailed procedures for measuring the rate of gas generation by grout made from synthetic tanks wastes or actual tank material. Objective is to measure the rate of gas generation for various gases (H₂, N₂O, etc.) produced when grout, prepared using tank waste, is heated at 65 C. Experi...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access
Corporate Authors: Westinghouse Hanford Company (Researcher), United States. Department of Energy. Richland Operations Office. (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C. : Oak Ridge, Tenn. : United States. Dept. of Energy ; distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1995.
Subjects:
Description
Summary:Disclosed are detailed procedures for measuring the rate of gas generation by grout made from synthetic tanks wastes or actual tank material. Objective is to measure the rate of gas generation for various gases (H₂, N₂O, etc.) produced when grout, prepared using tank waste, is heated at 65 C. Experiments will also be conducted using grout from synthetic tank waste, as practice. Purpose is to provide data for evaluation of safety risks presented by gas generation in the grout vault after making grout with tank waste, as verification/confirmation for gas generation rates for the ANL testing.
Item Description:Published through the Information Bridge: DOE Scientific and Technical Information.
01/04/1995.
"WHC-SD-WM-TP--180"
"DE95005623"
"35AF11201/35AF11202"
Person, J.C.
Physical Description:69 p.