Thermal-Hydraulics Modeling and Simulations of Hot Pool Using the SAS-CFD Coupled Code [electronic resource]

The main goal of this activity is to test the dynamic coupling of the SAS4A/SASSYS-1 (SAS) and CFD models, using a recently patched version of the SAS code intended to address an undocumented limitation that hindered the Versatile Test Reactor (VTR) simulation efforts in FY21. As described in previo...

Full description

Saved in:
Bibliographic Details
Online Access: Full Text (via OSTI)
Corporate Author: Argonne National Laboratory (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Argonne, Ill. : Oak Ridge, Tenn. : Argonne National Laboratory ; Distributed by the Office of Scientific and Technical Information, U.S. Department of Energy, 2022.

MARC

LEADER 00000nam a22000003u 4500
001 b12740554
003 CoU
005 20220712040000.0
006 m o d f
007 cr |||||||||||
008 221019e20220130||| o| f0|||||eng|d
035 |a (TOE)ost1875250 
035 |a (TOE)1875250 
040 |a TOE  |c TOE 
049 |a GDWR 
086 0 |a E 1.99:ANL-VTR-94 
086 0 |a E 1.99:ANL-VTR-94 
088 |a ANL-VTR-94 
245 0 0 |a Thermal-Hydraulics Modeling and Simulations of Hot Pool Using the SAS-CFD Coupled Code  |h [electronic resource] 
260 |a Argonne, Ill. :  |b Argonne National Laboratory ;  |a Oak Ridge, Tenn. :  |b Distributed by the Office of Scientific and Technical Information, U.S. Department of Energy,  |c 2022. 
300 |a Medium: ED :  |b digital, PDF file. 
336 |a text  |b txt  |2 rdacontent. 
337 |a computer  |b c  |2 rdamedia. 
338 |a online resource  |b cr  |2 rdacarrier. 
500 |a Published through Scitech Connect. 
500 |a 01/30/2022. 
500 |a "ANL-VTR-94." 
500 |a "Other: 174426." 
500 |a Vegendla, Prasad; Thomas, Justin; Fanning, Thomas;  
500 |a USDOE Office of Nuclear Energy - Versatile Test Reactor Program. 
520 3 |a The main goal of this activity is to test the dynamic coupling of the SAS4A/SASSYS-1 (SAS) and CFD models, using a recently patched version of the SAS code intended to address an undocumented limitation that hindered the Versatile Test Reactor (VTR) simulation efforts in FY21. As described in previous VTR calculation reports, the undocumented limitation in SAS v5.4 does not allow the user to activate the CFD coupling option during restart calculations. Since the analysts were unaware of this limitation, prior SAS-CFD simulation results for the protected station blackout (PSBO) transient were erroneous. Root-cause analysis was performed to determine the cause of this undocumented limitation in SAS v5.4, the SAS software was updated in a new patch, and the SAS-CFD simulations were repeated with this patched software. The results of the SAS-CFD simulations documented in this report show that the software patch does address the cited issue, and that the patched software indeed supports the activation of the CFD coupling model in restart calculations. The SAS development team will determine the schedule for implementing the patch in an official software release. This report documents updated SAS-CFD simulations of the PSBO transient response in the VTR. The hot pool is modeled with the CFD code STAR-CCM+, which is coupled at the flow boundaries to the SAS model of the primary heat transport system. SAS computes the mass flow rate and temperature at each core subassembly outlet, the thermal insulation cavity bypass, and the IHX inlet windows. CFD in turn computes the absolute pressure and temperature at each of these boundaries. The SAS code will ignore the temperature data at flow boundaries where flow is directed into the hot pool, i.e., at the core subassembly outlets unless flow reversal occurs. Similarly, CFD will ignore temperature data at boundaries where the flow is directed out of the hot pool, i.e., at the IHX inlets except under flow reversal. The focus of this work is to ensure that the SAS software patch addresses the undocumented limitation described in prior VTR calculation reports, rather than the accurate assessment of thermal stratification in the VTR during protected transients. This motivates the development of a new, simplified CFD model with a coarser mesh to accelerate the testing process. The updated model, and simplifying assumptions, are documented in this report. In future work, the thermal stratification assessment should be performed in more detail. The simplified CFD model can be improved by performing grid convergence studies sensitivity studies of turbulence parameters (e.g., Prandtl number, turbulence production and dissipation parameters) on temperature distributions and thermal stratification. 
536 |b AC02-06CH11357. 
710 2 |a Argonne National Laboratory.  |4 res. 
710 1 |a United States.  |b Department of Energy.  |b Office of Scientific and Technical Information  |4 dst. 
856 4 0 |u https://www.osti.gov/servlets/purl/1875250  |z Full Text (via OSTI) 
907 |a .b127405549  |b 02-28-23  |c 07-29-22 
998 |a web  |b 12-08-22  |c f  |d m   |e p  |f eng  |g    |h 0  |i 2 
956 |a Information bridge 
999 f f |i 7f3572ab-5328-591b-adea-b67e29c09ded  |s 013fe47c-b9e9-56e0-b2be-87dcfe4c3027 
952 f f |p Can circulate  |a University of Colorado Boulder  |b Online  |c Online  |d Online  |e E 1.99:ANL-VTR-94  |h Superintendent of Documents classification  |i web  |n 1