1 TeV pgun collisions, Double particles type, PARTICLE GUN generator [electronic resource] : pgun_2klong_angle05.
Particle gun for detector studies: A particle gun for two K-long mesons (KL, PID=130) separated by 0.5 degree. For every 20th events, the angular separation is reset to 0 degree, for easy tracking. The maximal separation is 10 degree. The eta is set to 0. Production at (x,y,z,t)=(0,0,0,0). Uniform d...
Saved in:
Online Access: |
Full Text (via OSTI) |
---|---|
Corporate Author: | |
Format: | Electronic eBook |
Language: | English |
Published: |
Argonne, Ill. : Oak Ridge, Tenn. :
Argonne National Laboratory ; Distributed by the Office of Scientific and Technical Information, U.S. Department of Energy,
2016.
|
Subjects: |
MARC
LEADER | 00000nam a22000003u 4500 | ||
---|---|---|---|
001 | b11016644 | ||
003 | CoU | ||
005 | 20191203000000.0 | ||
006 | m o d f | ||
007 | cr ||||||||||| | ||
008 | 200416e20160828||| o| f0|||||eng|d | ||
035 | |a (TOE)ost1575631 | ||
035 | |a (TOE)1575631 | ||
040 | |a TOE |c TOE | ||
049 | |a GDWR | ||
245 | 0 | 0 | |a 1 TeV pgun collisions, Double particles type, PARTICLE GUN generator |h [electronic resource] : |b pgun_2klong_angle05. |
260 | |a Argonne, Ill. : |b Argonne National Laboratory ; |a Oak Ridge, Tenn. : |b Distributed by the Office of Scientific and Technical Information, U.S. Department of Energy, |c 2016. | ||
300 | |a Other: PARTICLE GUN : |b digital, PDF file. | ||
336 | |a text |b txt |2 rdacontent. | ||
337 | |a computer |b c |2 rdamedia. | ||
338 | |a online resource |b cr |2 rdacarrier. | ||
500 | |a Published through Scitech Connect. | ||
500 | |a 08/28/2016. | ||
500 | |a Chekanov, S.; Nhan V Tran; | ||
500 | |a USDOE Office of Science (SC) | ||
520 | 3 | |a Particle gun for detector studies: A particle gun for two K-long mesons (KL, PID=130) separated by 0.5 degree. For every 20th events, the angular separation is reset to 0 degree, for easy tracking. The maximal separation is 10 degree. The eta is set to 0. Production at (x,y,z,t)=(0,0,0,0). Uniform distribution in Phi between -PI and PI. This sample has 3 subsamples for 10, 100 and 100 GeV energy (fixed). There are 100 files in each sample. The sample was designed for detector studies. | |
536 | |b AC02-06CH11357. | ||
650 | 7 | |a 72 physics of elementary particles and fields |2 local. | |
650 | 7 | |a Double particles |2 local. | |
650 | 7 | |a Particle gun |2 local. | |
650 | 7 | |a Monte carlo |2 local. | |
650 | 7 | |a Simulations |2 local. | |
650 | 7 | |a Particle physics |2 local. | |
650 | 7 | |a High energy physics |2 local. | |
710 | 2 | |a Argonne National Laboratory. |4 res |4 spn. | |
710 | 1 | |a United States. |b Department of Energy. |b Office of Scientific and Technical Information |4 dst. | |
856 | 4 | 0 | |u http://www.osti.gov/servlets/purl/1575631 |z Full Text (via OSTI) |
907 | |a .b110166449 |b 11-30-21 |c 05-11-20 | ||
998 | |a web |b 05-11-20 |c f |d m |e p |f eng |g |h 0 |i 1 | ||
956 | |a Information bridge | ||
999 | f | f | |i 73fc9b8b-7487-5c9a-a7b8-f644921a1bd2 |s 92de5059-efd4-5549-900b-1f3a15552c00 |
952 | f | f | |p Can circulate |a University of Colorado Boulder |b Online |c Online |d Online |i web |n 1 |