Status of the FARO/KROTOS melt-coolant interactions tests [electronic resource]

Results of FARO test L-19 are reported. It involved 155 kg of 80 w% UO₂+20 w% ZrO₂ at 3073 K quenched in 338-kg, 1-m-depth water at saturation at 5.0 MPa (i.e., 537 K). The test is compared with two former tests (L-06 and L-08) performed in similar conditions (1-m-depth water) but with reduced quant...

Full description

Saved in:
Bibliographic Details
Online Access: Online Access (via OSTI)
Corporate Author: U.S. Nuclear Regulatory Commission. Office of Nuclear Regulatory Research (Researcher)
Format: Government Document Electronic eBook
Language:English
Published: Washington, D.C. : Oak Ridge, Tenn. : U.S. Nuclear Regulatory Commission. Office of Nuclear Regulatory Research ; distributed by the Office of Scientific and Technical Information, U.S. Department of Energy, 1996.
Subjects:

Internet

Online Access (via OSTI)

Online

Holdings details from Online
Call Number: E 1.99: conf-9510156--vol.2
E 1.99: conf-9510156--vol.2 Available